EXPERIENCE THE most advanced Synthetic Blood Penetration Analyzer

M19 Synthetic Blood Penetration Analyzer (SBP-50) for technical textile — AI-based, ultra-high-precision testing. Standards: ASTM F1862, ASTM F1670.

Model: SBP-50 · Industry: Technical Textile

Technology principle

The M19 Synthetic Blood Penetration Analyzer (SBP-50) evaluates the resistance of protective and medical textiles to synthetic-blood and body-fluid penetration, projecting synthetic blood at defined volume, velocity and pressure to simulate real-world exposure. This determines a fabric’s protection against bloodborne pathogens. Referenced to ASTM F1862, ASTM F1670, ISO 16603 and ISO 22609, the SBP-50 gives medical-PPE manufacturers objective, traceable barrier data for masks, gowns and surgical fabrics.

Applications

  • Surgical masks and gowns
  • Isolation and coverall fabrics
  • Medical drapes
  • Barrier nonwovens
  • Protective medical laminates
  • Face-shield and hood fabrics

Key capabilities

  • Lightweight, compact and ergonomically engineered, the M19 Synthetic Blood Penetration Analyzer (SBP-50) pairs a 15" capacitive touchscreen with enhanced pressure- and flow-control hardware, so operators run a full technical textile test sequence with minimal training and markedly shorter cycle times. Available in aluminum or stainless-steel variants, it ships with real-time remote support, USB connectivity and remote-control automation. Domestic manufacturing in India and the USA keeps maintenance cost and downtime low, and a 2-year extended warranty is available.
  • Modern, low-training user interface
  • Lightweight and portable chassis
  • IP65 rated · GAMP 5 compliant
  • Three secure user levels — Operator, Supervisor and Administrator
  • Versatile connectivity — USB, Ethernet and Wireless LAN
  • Flexible reporting — built-in thermal printer or network / PDF / CSV export

Technical specifications

SpecificationValue
PressureProgrammable
CriteriaVisual + metrics
WorkflowStandardized method
ReportsBatch-ready

Standards compliance

  • ASTM F1862
  • ASTM F1670
  • ISO 16603
  • ISO 22609

Frequently asked questions

What does the SBP-50 measure for medical PPE?

It quantifies fluid-barrier performance: Synthetic-blood penetration pass/fail at set pressure High-velocity impact penetration (ASTM F1862) Barrier performance for bloodborne-pathogen protection Comparative barrier across fabric constructions

How does it outperform manual barrier testing?

Controlled projection volume, velocity and pressure with objective detection remove operator variability and produce standard-ready records.

How does the controlled-projection method improve accuracy?

The system: Delivers synthetic blood at defined volume and velocity Applies precise, repeatable pressure levels Detects penetration objectively Auto-calibrates for reproducibility

What are the advantages of domestic manufacturing?

Local build delivers: Faster service and local support Reduced lead time and spare-parts availability Lower import cost and easy customisation 2-year warranty with on-site support

Can it integrate into medical-PPE QA workflows?

Yes — secure records, connectivity and PDF/CSV export let barrier data feed development and lot acceptance.

How does it support standards compliance?

Alignment to ASTM F1862 / F1670 and ISO 16603 / 22609 plus tamper-proof records keeps barrier data audit-ready for certification.

Back to Technical Textile · All instruments · Request a quote