EXPERIENCE THE most advanced Synthetic Blood Penetration Analyzer
M19 Synthetic Blood Penetration Analyzer (SBP-50) for technical textile — AI-based, ultra-high-precision testing. Standards: ASTM F1862, ASTM F1670.
Model: SBP-50 · Industry: Technical Textile
Technology principle
The M19 Synthetic Blood Penetration Analyzer (SBP-50) evaluates the resistance of protective and medical textiles to synthetic-blood and body-fluid penetration, projecting synthetic blood at defined volume, velocity and pressure to simulate real-world exposure. This determines a fabric’s protection against bloodborne pathogens. Referenced to ASTM F1862, ASTM F1670, ISO 16603 and ISO 22609, the SBP-50 gives medical-PPE manufacturers objective, traceable barrier data for masks, gowns and surgical fabrics.
Applications
- Surgical masks and gowns
- Isolation and coverall fabrics
- Medical drapes
- Barrier nonwovens
- Protective medical laminates
- Face-shield and hood fabrics
Key capabilities
- Lightweight, compact and ergonomically engineered, the M19 Synthetic Blood Penetration Analyzer (SBP-50) pairs a 15" capacitive touchscreen with enhanced pressure- and flow-control hardware, so operators run a full technical textile test sequence with minimal training and markedly shorter cycle times. Available in aluminum or stainless-steel variants, it ships with real-time remote support, USB connectivity and remote-control automation. Domestic manufacturing in India and the USA keeps maintenance cost and downtime low, and a 2-year extended warranty is available.
- Modern, low-training user interface
- Lightweight and portable chassis
- IP65 rated · GAMP 5 compliant
- Three secure user levels — Operator, Supervisor and Administrator
- Versatile connectivity — USB, Ethernet and Wireless LAN
- Flexible reporting — built-in thermal printer or network / PDF / CSV export
Technical specifications
| Specification | Value |
|---|
| Pressure | Programmable |
| Criteria | Visual + metrics |
| Workflow | Standardized method |
| Reports | Batch-ready |
Standards compliance
- ASTM F1862
- ASTM F1670
- ISO 16603
- ISO 22609
Frequently asked questions
What does the SBP-50 measure for medical PPE?
It quantifies fluid-barrier performance: Synthetic-blood penetration pass/fail at set pressure High-velocity impact penetration (ASTM F1862) Barrier performance for bloodborne-pathogen protection Comparative barrier across fabric constructions
How does it outperform manual barrier testing?
Controlled projection volume, velocity and pressure with objective detection remove operator variability and produce standard-ready records.
How does the controlled-projection method improve accuracy?
The system: Delivers synthetic blood at defined volume and velocity Applies precise, repeatable pressure levels Detects penetration objectively Auto-calibrates for reproducibility
What are the advantages of domestic manufacturing?
Local build delivers: Faster service and local support Reduced lead time and spare-parts availability Lower import cost and easy customisation 2-year warranty with on-site support
Can it integrate into medical-PPE QA workflows?
Yes — secure records, connectivity and PDF/CSV export let barrier data feed development and lot acceptance.
How does it support standards compliance?
Alignment to ASTM F1862 / F1670 and ISO 16603 / 22609 plus tamper-proof records keeps barrier data audit-ready for certification.
Back to Technical Textile · All instruments · Request a quote